Portuguęs/Brasil Portuguęs/Brasil      English English      Espaņol Espaņol      
Hi Guest [ Sign Up or Sign In ]
Home About Us Services Machines For Sale Business For Sale Maintenance Technician Our Customers Contact Us
What you need?
Only available

Used machines for sale

Sterilization for cleanroom

Main brands:

, Sercon


Sterilization for cleanroom
An industrial clean room for sterilization is used in industrial environments for quality control and clean room purposes. In industrial environments, such as pharmaceutical, electronics or food manufacturing facilities, it is essential to maintain a clean and controlled environment to ensure the quality and safety of manufactured products. A "boundary greenhouse" may refer to a part of the environmental control system in a cleanroom. I will explain the functioning and general purpose of these structures:

Purpose of an Industrial Frontier Greenhouse for Clean Rooms:

An industrial frontier greenhouse is a critical part of a cleanroom that helps maintain a controlled environment free of contaminating particles. It is mainly used to control the passage of people and materials from the external area to the clean room area. The primary purpose of a boundary greenhouse is to minimize cross-contamination and maintain the integrity of the cleanroom environment.

Operation of an Industrial Frontier Greenhouse for Clean Rooms:

The operation of an industrial frontier greenhouse involves the creation of two distinct zones:

External Zone: This is the area that does not meet clean room requirements and may contain particles, contaminants and microorganisms. Generally, operators enter this zone from the outside environment.

Internal Zone (Clean Room): This is the clean room area, which is maintained under controlled conditions such as temperature, humidity and air purity. It must meet rigorous cleaning and particle control standards.

The operation of the border greenhouse involves the passage of materials or people from the external area to the internal area, ensuring that contamination is minimized. This is achieved through:

Differential Pressure: Generally, the cleanroom is kept under positive pressure with respect to the outside zone, which prevents contaminated air from entering the cleanroom when the boundary greenhouse is opened.

Air Filtration Systems: The frontier greenhouse may include air filtration systems that remove particles and contaminants from the air before it enters the cleanroom.

Clothing and Sanitation Procedures: People entering the cleanroom typically need to follow strict clothing and sanitation procedures, such as wearing protective clothing and washing hands and shoes.

Controlled Material Passages: The passage of materials from the external zone to the clean room is controlled, generally using specific doors and transfer systems.

Overall, an industrial boundary greenhouse is a crucial part of the environmental control system in a cleanroom, helping to maintain the quality and purity standards necessary for the production of contamination-sensitive products.

Sterilization of a frontier greenhouse, which is a critical part of a cleanroom environment in industrial facilities, is critical to maintaining high standards of cleanliness and contamination control. There are several sterilization methods that can be used depending on the specific needs and regulations of the facility. Some of the common sterilization methods include:

Heat Sterilization: Heat sterilization is a widely used method for frontier greenhouses. This can be achieved through techniques such as autoclaving, which uses steam at high pressure and temperature to destroy microorganisms. It is also possible to use dry ovens to heat the greenhouse to high temperatures for a specific period of time, killing any microorganisms present.

Ultraviolet Radiation (UV): Exposure to ultraviolet light is effective in destroying microorganisms. Border greenhouses can be equipped with UV lamps for air and surface sterilization.

Gamma Irradiation: This method involves exposing greenhouse surfaces and materials to gamma radiation. This is effective in sterilization, but requires specific equipment and strict regulations.

Chemical Disinfectants: Chemical disinfectants, such as hydrogen peroxide or peracetic acid, can be used to disinfect surfaces and materials within the boundary greenhouse. It is important to ensure that these chemicals are approved for use in cleanroom environments and that they are used appropriately to avoid chemical residues.

Sterilization by Filtration: Air systems in the frontier greenhouse can include high-efficiency filters that remove particles and microorganisms from the air before it enters the cleanroom area.

Vapor Hydrogen Peroxide (VHP): VHP is a gas sterilization technique that is used in some frontier greenhouse systems. It is effective in disinfecting surfaces and equipment.

It is important to note that the choice of sterilization method should be based on the specific needs of the facility, government regulations, and industry guidelines. Furthermore, regular maintenance and monitoring of the sterilization process is crucial to ensuring sterilization effectiveness and maintaining a clean environment in an industrial frontier greenhouse.
Double sterilization greenhouse for clean rooms Sercon
Double sterilization greenhouse for clean rooms Sercon

Machine code: 077-880

Brand: Sercon

Sterilization oven.

Brand: Sercon.

Model: ESA.

Litration: 2132L.

Dry steam sterilization.

Maximum temperature 220 ° C....




Visitation: Schedule date for visitation and check equipment availability. Merely illustrative images.
 

Closed your business?
Customers

 

Photos and images sent by email will be considered as ad authorization on our websites and marketing.
Camargo Industrial has no responsability for the data delivered by the advertiser, (Operation, technical, maintenance, warranties, technical delivery) and registration of the same data, exempting Camargo Industrial responsibilities on the veracity of the information described, civil and criminally.
The advertiser declares that the equipment is their property, settled without alienation, pending fiscal or judicial attachment.
Standard Work Safety of Machines and Equipment (NR12): 12.1.1. Camargo Industrial does not participate in the use phase construction, transport, assembly, installation, adjustment, operation, cleaning, maintenance, inspection, decommissioning and dismantling of machinery or equipment, any such liability of the seller attributes and / or buyer, relieving - any responsibility Camargo Industrial.
 
 
Camargo Industrial - Street Antonio Blanco, 1451 - Jardim Sao Joao Batista
ZIP Code: 13567-060 - Sao Carlos / SP - Brazil

Phones:

Sales: +55 (16) 3361-6681 / 3361-6682 / 3419-4644

Administrative: +55 (16) 3419-4648

Visitation: Schedule date for visitation and check equipment availability. Merely illustrative images.